Refrigerant Charging and Service Procedures for Air Conditioning

This book is dedicated to those who are eager to learn the HVACR Trade and Refrigerant Charging/ Troubleshooting Practices. In this book, you will find Step by Step Procedures for preparing an air conditioning and heat pump system for refrigerant, reading the manifold gauge set, measuring the refrigerant charge level, and troubleshooting problems with the system’s refrigerant flow. This book differs from others as it gives key insights into each procedure along with tool use from a technician’s perspective, in language that the technician can understand.

 

This book explains the refrigeration cycle of air conditioners and heat pumps, refrigerant properties, heat transfer, the components included in the system, the roles of each component, airflow requirements, and common problems.

 

Procedures Included:

  ·Pump Down

  ·Vacuum and Standing Vacuum

   Test

  ·Recovery and Recovery Bottle use

  ·Refrigerant Manifold Gauge Set

   and Hose Connections

  ·Service Valve Positions and Port

   Access

  ·Preparation of the System for

   Refrigerant

  ·Refrigerant Charging and

   Recovery on an Active System

  ·Troubleshooting the Refrigerant

   Charge and System Operation

Refrigerant Charging Book Cover
Back Cover of the Book

Paperback Now Available in our Store! $78.99

Paperback Now Available en Español! $78.98

book
ebook

The E-Book

Our E-Book contains the same great content as our Paperback with the convenience of being available right on your desktop or mobile device!

If you are looking for an E-Reader to open our book on your device, be sure to check out the free options below!

Adobe Digital Editions

For use on PC and Mac computers

Google Play Books

For use on Android and Google devices

Apple Books

For use on iPhones and iOS devices

Ebook combo pic

Get the E-Book in our Store! $39.99

Adobe Digital Editions logo
Google Play Books icon
Apple_Books icon
Spanish

Sample Pages Below

Table of Contents
& Select Pages

*Sample images are not full, high resolution

Danfoss Ad

Table of Contents 1

Book outline 1

Page 196

Refrigerant Charging and Service Procedu

Table of Contents 4

Book outline 4

Page 58

Refrigerant Charging and Service Procedu

Page 161

Refrigerant Charging and Service Procedu

Table of Contents 2

Book outline 2

Table of Contents 5

Book outline 5

Page 61

Refrigerant Charging and Service Procedu

Page 195

Refrigerant Charging and Service Procedu

Table of Contents 3

Book outline 3

Table of Contents 6

Book outline 6

Page 160

Refrigerant Charging and Service Procedu
Danfoss Ad
Asurity-Digital-Ads_High_Res_1080x360.jp
ACSERVICETECH-AccuTrak-Video-Ad-3-Web-Op

The Workbook

Workbook

This workbook is a direct compliment to the "Refrigerant Charging and Service Procedures for Air Conditioning" text. Each copy of the book includes a detached answer key for quick reference and use. This workbook follows the text chapter by chapter providing over 1,000 supportive questions and problems to test your understanding of the various procedures, methods, and steps stated in the book. This workbook can also help readers retain information such as the refrigeration cycle and components used in each system. Custom images are used to display charging scenarios and troubleshooting.

 

Test your knowledge as you solve each problem and question!

Workbook and Answer Key

Workbook
Now Available in our Store! $34.99

Sample Pages Below

Select Pages

*Sample images are not full, high resolution

Page 36

Page 34

Page 34

Page 47

Page 47

Page 78

Page 78
Page 36
cards

The Cards

Chart Card Right With NO Background.png

These three UPDATED HVAC quick reference polystyrene cards are double sided and
designed to be used with Air Conditioners and Heat Pumps to measure the refrigerant charge
level in a unit, charge refrigerant, troubleshoot refrigerant based problems, and measure heat
transfer to determine if there is a problem.
 

  • Use the P/T Chart to find the Saturated Temperature of the common refrigerants R-32, R454B,      R-410A, R-22, R-407C, R-422B, and R-438A.

  • Use the Guide to determine how to find the Bubble and Dew Saturated Temps of Blend  Refrigerants.

  • Use the Refrigerant Weight Chart to calculate the amount of refrigerant needed per foot of tubing R-32, R454B, R-410A, R-22, R-407C, R-422B, and R-438A.

  • Use the Guide to weigh in the full or partial refrigerant charge into an empty vacuumed unit.

  • Find the Target Subcooling to measure the refrigerant level of systems with a TXV metering device.​

  • Use Subcooling to determine if a system is undercharged, correctly charged, or overcharged.

  • Use Delta T to determine if the system is exchanging heat properly.

  • Find the Target Superheat to measure the refrigerant level of systems with a fixed orifice metering device.

  • Use Total Superheat to determine if a system is undercharged, correctly charged, or overcharged.

HVAC Reference Cards Now Available in our Store! $27.99

Bundle and Save!

Bundle

Get $5 off the Refrigerant Charging E-Book when you buy the Paperback, Workbook, and Card Combo and use promo code digitalrefrig20
at checkout!

Ebook combo pic
bundle option of book workbook and cards

Paperback, Workbook, and Card Combo

Save $12

$141.99

$129.99

Paperback and Card Combo

Save $7

$106.99

$99.99

bundle option of book and cards
bundle option workbook and cards

Workbook, and Card Combo

Save $4

$62.99

$54.99

Paperback and Workbook Combo

Save $9!

$113.99

$104.99

bundle option book and workbook

Mini Split & Refrigerant Charging Paperback Combo

Save $15!

$178.99

$163.99

Mini Split & Refrigerant Charging Combo

Save $32!

$281.99

$249.99

Posters

Posters
Sample of Posters

This poster bundle includes 7 unique, high quality, professionally printed posters. Each poster focuses on the refrigeration cycle for various types of HVAC/R systems and includes all major refrigerant components within the systems. The 7 specific posters included in this bundle:

 

  • The Basic Refrigeration Cycle

  • The Refrigeration Cycle of an Air Conditioner

  • Heat Pump Refrigeration Cycle: Air Conditioning

  • Heat Pump Refrigeration Cycle: Heating

  • Ductless Mini-Split Refrigeration Cycle: Air Conditioning

  • Ductless Mini-Split Refrigeration Cycle: Heating

  • Walk-In Box Refrigeration Cycle

 

Poster bundles are available in two sizes. 

Select either 23" x 35" or 12" x 18"

7pk of HVAC/R Refrigeration Cycle Posters Now Available in our Store!

Small Posters: $34.99

Large Posters: $44.99

Powerpoints

Powerpoints

This a read-only powerpoint that is split up into 7 distinct sections of slides in order to teach the basics for checking the refrigerant charge of an air conditioning or heat pump system during A/C mode. Make sure to view this powerpoint in "Presenter View" in order to see the notes for each slide. 

 

•Slides 1-33 Reading Compound Gauges

  & Understanding Saturated Refrigerant

•Slides 34-42 Airflow and Metering

  Device Type

•Slides 43-61 Connecting the Gauge Set

  and Air Purging

•Slides 62-73 Methods for Checking the

  Charge

•Slides 74-96 Checking the Charge of a

  Running A/C System

•Slides 97- 102 Delta-T Measurements

•Slides 103- 114 The Disconnect

  Procedure

This PowerPoint Bundle includes 11 distinct PowerPoint Presentations with presenter notes, that are designed to teach the refrigeration cycle on various systems. 

​

The Refrigeration Cycle PowerPoint Presentation Bundle includes the following presentations:

 

1. Basic Refrigeration Cycle (Detailed)

    – 6 Slides

2. The Refrigeration Cycle of an Air

    Conditioner (Detailed) – 23 Slides

3. Heat Pump Refrigeration Cycle, Air

    Conditioning (Detailed) – 24 Slides

4. Heat Pump Refrigeration Cycle,

    Heating (Detailed) – 24 Slides

5. Ductless Mini-Split Refrigeration Cycle,

    Air Conditioning (Detailed) – 28 Slides

6. Ductless Mini-Split Refrigeration Cycle,

    Heating (Detailed) – 28 Slides

7. Walk-In Box Refrigeration Cycle

    (Detailed) – 30 Slides

8. Basic Refrigeration Cycle – 6 Slides

9. The Refrigeration Cycle of an Air

    Conditioner – 23 Slides

10. Heat Pump Refrigeration Cycle, Air

     Conditioning – 24 Slides

11. Heat Pump Refrigeration Cycle,

     Heating – 24 Slides

Powerpoint Pic

This PowerPoint Bundle includes 11 distinct PowerPoint Presentations with presenter notes, that are designed to teach the refrigeration cycle on various systems. 

​

The Refrigeration Cycle PowerPoint Presentation Bundle includes the following presentations:

 

1. Basic Refrigeration Cycle (Detailed) – 6 Slides

2. The Refrigeration Cycle of an Air Conditioner (Detailed)

    – 23 Slides

3. Heat Pump Refrigeration Cycle, Air Conditioning             

    (Detailed) – 24 Slides

4. Heat Pump Refrigeration Cycle, Heating (Detailed)

    – 24 Slides

5. Ductless Mini-Split Refrigeration Cycle, Air Conditioning

    (Detailed) – 28 Slides

6. Ductless Mini-Split Refrigeration Cycle, Heating

    (Detailed) – 28 Slides

7. Walk-In Box Refrigeration Cycle (Detailed) – 30 Slides

8. Basic Refrigeration Cycle – 6 Slides

9. The Refrigeration Cycle of an Air Conditioner – 23 Slides

10. Heat Pump Refrigeration Cycle, Air Conditioning

      – 24 Slides

11. Heat Pump Refrigeration Cycle, Heating – 24 Slides

This a read-only powerpoint that is split up into 7 distinct sections of slides in order to teach the basics for checking the refrigerant charge of an air conditioning or heat pump system during A/C mode. Make sure to view this powerpoint in "Presenter View" in order to see the notes for each slide. 

 

Slides 1-33 Reading Compound Gauges & Understanding Saturated Refrigerant

Slides 34-42 Airflow and Metering Device Type

Slides 43-61 Connecting the Gauge Set and Air Purging

Slides 62-73 Methods for Checking the Charge

Slides 74-96 Checking the Charge of a Running A/C System

Slides 97- 102 Delta-T Measurements

Slides 103- 114 The Disconnect Procedure

PowerPoint Presentations Now Available in our Store!

Basics for Checking the Charge Presentation: $39.99

Refrigeration Cycle Presentation Bundle: $49.99

Join Our Updates List!

AC Service Tech HVAC Training is made possible by continued support from our visitors, customers, and support from these Sponsors!

NAVAC LOGO Black_edited.png
Accutrak Logo
TruTech-Tools-Logo-Main (3)[528].png
HavenRGB-FC w_grey horz.png

AC SERVICE TECH, LLC

Updates List

Thanks for submitting!

Thanks for all your continued support! I appreciate all the comments, questions, and responses that I receive from each of you. I look forward to responding to many more! If you have an HVACR related question, drop it in the comment section of one of the YouTube videos at the AC Service Tech YouTube Channel and I will do my best to respond.

 

For business related inquires email us at info@acservicetech.com

Check back regularly as we are always updating and improving this website!

© 2026 AC Service Tech, LLC.

bottom of page