**2nd Edition**
Refrigerant Charging & Service Procedures for Air Conditioning Book

118 Video Play List

This list of 118 VIDEOS correlates to the 2nd Edition Refrigerant Charging & Service Procedures

for Air Conditioning Paperback version.

​

If you have an E-book, most ereaders count the cover page, preamble, and table of contents as pages so the page numbers are pushed back exactly 12 pages. For example, on the list below, "Pg 13 Basic Refrigeration Cycle" would actually be pg 25 in an E-book.

 

Pg 1 Book Introduction https://youtube.com/shorts/G6S0ZIwjCMM
Pg 1 What Does the Term Air Conditioning mean?   https://www.youtube.com/shorts/roD2A0Hmmho

Pg 4 Carbon Dioxide History https://youtu.be/dU-vbcf7Gv8

Pg 6 & 333 A2L Refrigerants R-32 and R-454B https://youtu.be/fpmCCmCFQLA

Pg 7 A2L Refrigerant Bottles https://youtube.com/shorts/FCxuwblMkPc

Pg 13 Basic Refrigeration Cycle https://youtu.be/WdS5tlPJGZc

Pg 17 4 Basic Components of an AC Unit  https://youtube.com/shorts/fe5QsBaXB1Q

Pg 26 How Refrigerant Works in an Air Conditioner https://youtu.be/e4Q7A3gIEmE

Pg 27 Air Handler and Heat Pump Explained https://youtu.be/xt5KnHH4J8s

Pg 31 Heat Pump Refrigerant Cycle https://youtu.be/t3YMFXLPBRE

Pg 34 Explaining Subcooling Quickly https://youtube.com/shorts/vp8YNhbmywg

Pg 36 Explaining Superheat Quickly https://youtube.com/shorts/8RbKLHDk-zY

Pg 43 Determining the Refrigerant in a Recovery Bottle https://youtu.be/PvlvZsDCgYU

Pg 48 Temperature Glide https://youtube.com/shorts/FQaeidodKBc

Pg 51 Calibrating a Temp Meter and Sensors https://youtu.be/vdEoz6xp9R0

Pg 61 Manifolds, Gauge Stubs, and Probes https://youtu.be/FyVdQEm23_o

Pg 62 Evolution of the Refrigerant Manifold Gauge Set https://youtu.be/NKB0Tq41cOg

Pg 65 CoreMax Valve and Port Assembly https://youtu.be/yvprlk4C6vA

Pg 70 Tips for Connecting to Refrigerant Ports https://youtu.be/0PCdVkxGokY

Pg 71 Refrigerant Hose End Fittings https://youtu.be/qJgxe0vUyfw

Pg 72 Connecting to the Ports, Manifold Gage Set https://youtu.be/4pJNB0l2Vjo

Pg 81 Uses of a VCRT https://youtube.com/shorts/zcFazXvZjB0

Pg 85 Two Position Service Valves https://youtu.be/WlJTY75oSqE

Pg 86 Service Valve Types and Access Fittings https://youtu.be/J0hyVhJyyD0

Pg 87 Three Position Service Valves https://youtu.be/9hN7u8iT8vI

Pg 90 Measuring Superheat & Subcooling https://youtu.be/2SEDe0v8VPY

Pg 91 Before Checking the Refrigerant Charge https://youtu.be/NOWQsrjm4AY

Pg 95 Checking the Charge, Subcooling https://youtu.be/eQgquFngPUM

Pg 95 & 251 R-32 and R-454B Checking the Charge https://youtu.be/rRvYVH0g218

Pg 99 Superheat & Total Superheat Explained https://youtu.be/vLGzCOUf1X8

Pg 101 Tools to Check Wet Bulb Temperature https://youtu.be/bUU8zKfr22g

Pg 103 Finding Target Superheat to Check the Charge https://youtu.be/MJMe9PPNjI8

Pg 104 Checking the Charge, Total Superheat Method https://youtu.be/DLDgfj5s4qg

Pg 104 Measuring the Refrigerant Charge, Fixed Orifice Systems https://youtu.be/cQgwrFxm_iQ

Pg 105 Methods for Checking the Refrigerant Levels https://youtu.be/EHzDDcnzcH8

Pg 105 Checking the Charge with Superheat https://youtu.be/sCIsw2FKC0M

Pg 107 Explaining Delta T https://youtu.be/VwHAMwJReog

Pg 108 Condensate From an Air Conditioner https://youtube.com/shorts/wS8ea32Jypg

Pg 109 Subcooling & Superheat, TXVs & Fixed Orifices https://youtu.be/ZE7oiVsVpfU

Pg 110 Check R-22 Refrigerant Charge, Subcooling https://youtu.be/NUKkwqDNq1E

Pg 110 Check R-410A Refrigerant Charge, Subcooling https://youtu.be/0zsckt86Who

Pg 110 Check R-410A Refrigerant Charge, Subcooling, More Methods https://youtu.be/sUiyiUjVpWc

Pg 111 Check R-410A Refrigerant Charge, Superheat https://youtu.be/hgJbuaWmkus

Pg 111 R-22 & R-410A AC Operating Pressures https://youtu.be/5pQUkG43gAI

Pg 111 Check the Charge on a TXV System, Subcooling https://youtube.com/shorts/Q6smzWNAz0k

Pg 122 What is a Liquid Vaporizer? https://youtu.be/42fPODYfLq8

Pg 141 Charging & Recovery, Digital Probes/Gauges https://youtu.be/obZgCt5d8bg

Pg 142 Charging Refrigerant, Wireless Probes https://youtu.be/saOTWm038JE

Pg 143 Leak Testing at the Ports https://youtu.be/xyBM4PLQXK0

Pg 150 Charging Refrigerant, the Subcooling Method  https://youtu.be/9l3n7yQ_N5k

Pg 152 Charging R-410A into an Air Conditioner, Low https://youtu.be/-pN9EoUZX8c

Pg 158 Methods for Recovering Refrigerant  https://youtu.be/yXJNuMmEPog

Pg 164 Refrigerant Recovery Tips https://youtu.be/DW2nf5bDoXY

Pg 165 Preparation of a Recovery Bottle https://youtu.be/DS8m0fYw48Q

Pg 171 Step by Step Refrigerant Recovery https://youtu.be/8pDp-q2dr_g

Pg 172 Recovery Machine Hose Setups https://youtu.be/oOMlOvOsFk8

Pg 172 Refrigerant Recovery Preparation & Procedure https://youtu.be/5XMlQCfdiu8

Pg 174 Refrigerant Recovery Procedure https://youtu.be/6F-u55EoMcU

Pg 182 The Pump Down Procedure https://youtu.be/xkQ6cxkaps4

Pg 186 Line Set Cleaning Methods https://youtu.be/sDji7wSt2MA

Pg 186 Eccentric Flaring Tools https://youtu.be/eF1e39Q6PaU

Pg 187 Silver Soldering & Brazing https://youtu.be/hrXX4IjjChM

Pg 188 Brazing and Leak Testing an Air Conditioner https://youtu.be/E1lEZwgmW9w

Pg 194 Where to Find Leaks on AC Units https://youtu.be/mjBdlwe687A

Pg 195 Ultrasonic Leak Detector https://youtu.be/JbXxE-WlQdo

Pg 202 Vacuum Procedure Tips https://youtu.be/rhmqHBi9a-o

Pg 203 Vacuum Pump Hose Setups https://youtu.be/TllrD0Mt2LU

Pg 204 Single vs Two Hose Vacuum Setup https://youtu.be/J4QvgpYFS9U

Pg 212 Step By Step Vacuum Pump Setup https://youtu.be/_VX9tlznCJQ

Pg 215 Vacuuming, Weighing Refrigerant, Checking the Charge https://youtu.be/PfdL3kZ3C6I

Pg 221 Vacuum Gauge Problems https://youtu.be/Ks3MtPmXDUE

Pg 223 Vacuum Pump Oil Basics https://youtu.be/09wD3pj3P2s

Pg 225 Triple Evacuation Method https://youtu.be/81EeY7SFYJc

Pg 227 Checking the Charge, Charging Jacket https://youtu.be/OmQQcjmNLgw

Pg 228 Checking the Charge, Low Outdoor Temps https://youtu.be/_hAkQpLT35g

Pg 229 Metering Device Bypass Features https://youtu.be/LdwrtJOszq0

Pg 231 Measuring Superheat & Subcooling without Pressure https://youtu.be/LWW6p6EnrmQ

Pg 243 Ambient + Rules https://youtu.be/3rVxcFIFyrk

Pg 245 Frozen Evaporator Coil Troubleshooting https://youtu.be/wZctpvMtXMM

Pg 245 Low Saturated Temperatures & Pressures https://youtu.be/gsgC6mV4Ip0

Pg 245 Why an Evaporator Coil Freezes https://youtu.be/fGZmQcLZ-5E

Pg 245 Checking Very Low Refrigerant Charge https://youtu.be/Oekdgkw4dys

Pg 246 Troubleshooting a Frozen Suction Line https://youtu.be/uW5sMlWr2WY

Pg 247 Low Indoor Airflow Troubleshooting https://youtu.be/ob44e8fVhwk

Pg 248 Frozen Indoor Coil, Low Refrigerant Charge https://youtu.be/gD-N6Q60Hdg

Pg 249 Liquid Line Restriction https://youtu.be/_x1aOij_uOI

Pg 250 Liquid Line Restriction, Low Airflow, Low Charge https://youtu.be/zOd2G10F-YY

Pg 250 Liquid Line Restriction Explained https://youtu.be/_yLMv7T2hhM

Pg 269 Wrong TXV for the Refrigerant in the System https://youtu.be/eZbWp4DEXBI

Pg 271 Airflow Basics  https://youtu.be/XqigOg-Bh90

Pg 272 Adjusting HVAC Blower Speed CFM https://youtu.be/f79rrGsWNvM

Pg 273 Measuring Airflow, Temp Rise Formula https://youtu.be/agAfV3Yqb7U

Pg 275 Measuring Airflow CFM, Hot Wire Anemometer https://youtu.be/0wWYsAn6eGo

Pg 278 Measuring Airflow CFM, TrueFlow Grid https://youtu.be/89IKljbgKgA

Pg 281 Measuring Static Pressure https://youtu.be/eFmDmk1Siqc

Pg 282 Finding Airflow Problems https://youtu.be/umJe1ow45I8

Pg 284 Low Airflow Causes https://youtu.be/T5eBsC_MZAI

Pg 286 Determining if an AC Coil is Clogged with Dust https://youtu.be/CLRMISQCg0A

Pg 287 Measuring Duct Leakage https://youtu.be/eqXR1J-JnRQ

Pg 289 Metering Device Types https://youtu.be/-4ZPUkxYkLo

Pg 291 Replacing a Piston with a TXV https://youtu.be/ETiXUeJG5tc

Pg 296 TXV, Superheat https://youtube.com/shorts/fc3eTzlgFCg

Pg 296 TXV Explained https://youtu.be/cORHWATpwUc

Pg 297 The 3 TXV Operations https://youtu.be/WkgshvMOx00

Pg 298 What’s Inside a TXV? https://youtu.be/p2XFT9j4nFw

Pg 300 Should You Replace a Bad TXV with a Piston? https://youtu.be/Cd_2-x3kdyY

Pg 302 LEV/EEV Operation and Troubleshooting https://youtu.be/B_j73X0gxC0

Pg 303 Explaining EEVs https://youtube.com/shorts/nsLMz2nRSwA

Pg 303 EEV Operations and Testing https://youtu.be/LzvVjvUpOVM

Pg 311 Scroll Compressor Operation https://youtu.be/e9vORn5Vwuc

Pg 318 Line Set Corrosion https://youtu.be/4WCnz34SiX8

Pg 324 Suction Line Accumulator Tank Explained https://youtu.be/WePMCkeJm5U

Pg 324 Mini Split Accumulator Tank https://youtube.com/shorts/V-xGxG5wOEc

Pg 326 Heat Pump Reversing Valve https://youtu.be/QLxQQElP1nA

Pg 330 Walk-In Box Refrigeration Cycle https://youtu.be/wjeoHrP9Nkg

Pg 330 Liquid Line Receiver Tank https://youtu.be/S9bYjfdLmJ8

Pg 331 Liquid Line Solenoid Valvehttps://youtu.be/fnny2VpdHiI

Pg 335 R-454B Dissipation Control Board Installation https://youtu.be/_SDRKdZ0WX4

​

If you have not yet purchased our Refrigerant Charging & Service Procedures book, be sure to check it out! It is available as a Paperback and E-book!

AC Service Tech HVAC Training is made possible by continued support from our visitors, customers, and support from these Sponsors!

NAVAC LOGO Black_edited.png
Accutrak Logo
TruTech-Tools-Logo-Main (3)[528].png
HavenRGB-FC w_grey horz.png

AC SERVICE TECH, LLC

Updates List

Thanks for submitting!

Thanks for all your continued support! I appreciate all the comments, questions, and responses that I receive from each of you. I look forward to responding to many more! If you have an HVACR related question, drop it in the comment section of one of the YouTube videos at the AC Service Tech YouTube Channel and I will do my best to respond.

 