The Mini Split Book

Mini Split Cover long

Inverter Mini Split Operation and Service Procedures

 

        The demand for inverter mini split system installations is growing rapidly due to the versatility, functionality, and electrical efficiency of these units. As a result, inverter mini split system installations and servicing are becoming more common for individuals in the HVACR trade. Technicians must know the step-by-step service procedures associated with these systems and how they differ from traditional single speed systems.

​

        This book was written to help demystify the operation of inverter mini split systems and to explain associated concepts and procedures, in a language that is easy to understand. System parts are examined individually, electrical/mechanical operation is discussed, and related troubleshooting steps are given. By examining each component individually, readers can more easily digest the information and build upon their knowledge, as they progress through the text. The goal of this book is to equip technicians with the knowledge they need to service these complex systems.

​

Procedures Included:

 · Line Set Connection

 · Leak Testing and Vacuuming

 · Charging and Recovery

 · Guidance on Checking the Charge

 · Power and Communication Wiring

 · Electrical Component Troubleshooting

 · Common Problems and Diagnosis

Mini Split Paperback
Mini Split Book Final Front Cover

Refrigerant Charging and Service Procedures for Air Conditioning

The demand for inverter mini split system installations is growing rapidly due to the versatility, functionality, and electrical efficiency of these units. As a result, inverter mini split system installations and servicing are becoming more common for individuals in the HVACR trade. Technicians must know the step-by-step service procedures associated with these systems and how they differ from traditional single speed systems. 

 

This book was written to help demystify the operation of inverter mini split systems and to explain associated concepts and procedures, in a language that is easy to understand. System parts are examined individually, electrical/mechanical operation is discussed, and related troubleshooting steps are given. By examining each component individually, readers can more easily digest the information and build upon their knowledge, as they progress through the text. The goal of this book is to equip technicians with the knowledge they need to service these complex systems.

 

Procedures Included:

 · Line Set Connection

 · Leak Testing and Vacuuming

 · Charging and Recovery

 · Guidance on Checking the Charge

 · Power and Communication Wiring

 · Electrical Component Troubleshooting

 · Common Problems and Diagnosis

Mini Split Cover
Mini Split Ebook

The Mini Split E-Book

Mini Split Book Cover with Binding no excess

Paperback Now Available in our Store! $99.99

Our E-Book contains the same great content as our Paperback with the convenience of being available right on your desktop or mobile device!

If you are looking for an E-Reader to open our book on your device, be sure to check out the free options below!

Adobe Digital Editions logo

Adobe Digital Editions

For use on PC and Mac computers

Google Play Books icon

Google Play Books

For use on Android and Google devices

Apple_Books icon

Apple Books

For use on iPhones and iOS devices

Ebook combo pic

Get the E-Book in our Store! $49.99

Sample Pages Below

Table of Contents
& Select Pages

*Sample images are not full, high resolution

Danfoss Ad

Table of Contents 1

Book outline 1

Page 196

Refrigerant Charging and Service Procedu

Table of Contents 4

Book outline 4

Page 58

Refrigerant Charging and Service Procedu

Page 161

Refrigerant Charging and Service Procedu

Table of Contents 2

Book outline 2

Table of Contents 5

Book outline 5

Page 61

Refrigerant Charging and Service Procedu

Page 195

Refrigerant Charging and Service Procedu

Table of Contents 3

Book outline 3

Table of Contents 6

Book outline 6

Page 160

Refrigerant Charging and Service Procedu

The  Mini Split Workbook

Mini Split Book Video List

Follow along with our 

Mini Split  Book using these 45 videos!

This workbook is a direct compliment to the “Inverter Mini Split Operation and Service Procedures” text. This workbook follows the text chapter by chapter providing over 1,300 supportive questions and problems to test your understanding of the various procedures, methods, and steps stated in the book. This workbook can also help readers retain information such as the operation of mini split systems and how the components function and interact. Custom images are used to assess understanding of various component parts and procedures.

Test your knowledge and increase your skills as you solve each problem and question!

Mini Split Workbook
Mini Split Workbook with Answer Key no background.png

Mini Split Workbook
Now Available in our Store! $39.99

Sample Pages Below

Select Pages

*Sample images are not full, high resolution

Page 49

Page 12

Mini Split Workbook Sample Page 12.jpg

Page 54

Mini Split Workbook Sample Page 54.jpg

Page 94

Mini Split Workbook Sample Page 94.jpg
Mini Split Workbook Sample Page 49.jpg
MSBundle

Bundle and Save!

Mini Split Paperback & Workbook Combo

Save $10

$129.99

$139.99

NEW Refrigerant Charging, Mini Split & Card Combo

Save $22

$285.99

$307.99

New Refrigerant Charging & Mini Split Paperback Combo

Save $14

$185.99

$199.99

Posters

Posters

wix posters page

This poster bundle includes 7 unique, high quality, professionally printed posters. Each poster focuses on the refrigeration cycle for various types of HVAC/R systems and includes all major refrigerant components within the systems. The 7 specific posters included in this bundle:

 

  • The Basic Refrigeration Cycle

  • The Refrigeration Cycle of an Air Conditioner

  • Heat Pump Refrigeration Cycle: Air Conditioning

  • Heat Pump Refrigeration Cycle: Heating

  • Ductless Mini-Split Refrigeration Cycle: Air Conditioning

  • Ductless Mini-Split Refrigeration Cycle: Heating

  • Walk-In Box Refrigeration Cycle

 

Poster bundles are available in two sizes. 

Select either 23" x 35" or 12" x 18"

7pk of HVAC/R Refrigeration Cycle Posters Now Available in our Store!

Small Posters: $34.99

Large Posters: $44.99

Powerpoints

Powerpoints

This a read-only powerpoint that is split up into 7 distinct sections of slides in order to teach the basics for checking the refrigerant charge of an air conditioning or heat pump system during A/C mode. Make sure to view this powerpoint in "Presenter View" in order to see the notes for each slide. 

 

•Slides 1-33 Reading Compound Gauges

  & Understanding Saturated Refrigerant

•Slides 34-42 Airflow and Metering

  Device Type

•Slides 43-61 Connecting the Gauge Set

  and Air Purging

•Slides 62-73 Methods for Checking the

  Charge

•Slides 74-96 Checking the Charge of a

  Running A/C System

•Slides 97- 102 Delta-T Measurements

•Slides 103- 114 The Disconnect

  Procedure

This PowerPoint Bundle includes 11 distinct PowerPoint Presentations with presenter notes, that are designed to teach the refrigeration cycle on various systems. 

​

The Refrigeration Cycle PowerPoint Presentation Bundle includes the following presentations:

 

1. Basic Refrigeration Cycle (Detailed)

    – 6 Slides

2. The Refrigeration Cycle of an Air

    Conditioner (Detailed) – 23 Slides

3. Heat Pump Refrigeration Cycle, Air

    Conditioning (Detailed) – 24 Slides

4. Heat Pump Refrigeration Cycle,

    Heating (Detailed) – 24 Slides

5. Ductless Mini-Split Refrigeration Cycle,

    Air Conditioning (Detailed) – 28 Slides

6. Ductless Mini-Split Refrigeration Cycle,

    Heating (Detailed) – 28 Slides

7. Walk-In Box Refrigeration Cycle

    (Detailed) – 30 Slides

8. Basic Refrigeration Cycle – 6 Slides

9. The Refrigeration Cycle of an Air

    Conditioner – 23 Slides

10. Heat Pump Refrigeration Cycle, Air

     Conditioning – 24 Slides

11. Heat Pump Refrigeration Cycle,

     Heating – 24 Slides

ac book powerpoint

This PowerPoint Bundle includes 11 distinct PowerPoint Presentations with presenter notes, that are designed to teach the refrigeration cycle on various systems. 

​

The Refrigeration Cycle PowerPoint Presentation Bundle includes the following presentations:

 

1. Basic Refrigeration Cycle (Detailed) – 6 Slides

2. The Refrigeration Cycle of an Air Conditioner (Detailed)

    – 23 Slides

3. Heat Pump Refrigeration Cycle, Air Conditioning             

    (Detailed) – 24 Slides

4. Heat Pump Refrigeration Cycle, Heating (Detailed)

    – 24 Slides

5. Ductless Mini-Split Refrigeration Cycle, Air Conditioning

    (Detailed) – 28 Slides

6. Ductless Mini-Split Refrigeration Cycle, Heating

    (Detailed) – 28 Slides

7. Walk-In Box Refrigeration Cycle (Detailed) – 30 Slides

8. Basic Refrigeration Cycle – 6 Slides

9. The Refrigeration Cycle of an Air Conditioner – 23 Slides

10. Heat Pump Refrigeration Cycle, Air Conditioning

      – 24 Slides

11. Heat Pump Refrigeration Cycle, Heating – 24 Slides

This a read-only powerpoint that is split up into 7 distinct sections of slides in order to teach the basics for checking the refrigerant charge of an air conditioning or heat pump system during A/C mode. Make sure to view this powerpoint in "Presenter View" in order to see the notes for each slide. 

 

Slides 1-33 Reading Compound Gauges & Understanding Saturated Refrigerant

Slides 34-42 Airflow and Metering Device Type

Slides 43-61 Connecting the Gauge Set and Air Purging

Slides 62-73 Methods for Checking the Charge

Slides 74-96 Checking the Charge of a Running A/C System

Slides 97- 102 Delta-T Measurements

Slides 103- 114 The Disconnect Procedure

PowerPoint Presentations Now Available in our Store!

Basics for Checking the Charge Presentation: $39.99

Refrigeration Cycle Presentation Bundle: $49.99

Join Our Updates List!

AC Service Tech HVAC Training is made possible by continued support from our visitors, customers, and support from these Sponsors!

NAVAC LOGO Black_edited.png
Accutrak Logo
TruTech-Tools-Logo-Main (3)[528].png
HavenRGB-FC w_grey horz.png

AC SERVICE TECH, LLC

Updates List

Thanks for submitting!

Thanks for all your continued support! I appreciate all the comments, questions, and responses that I receive from each of you. I look forward to responding to many more! If you have an HVACR related question, drop it in the comment section of one of the YouTube videos at the AC Service Tech YouTube Channel and I will do my best to respond.

 

For business related inquires email us at info@acservicetech.com

Check back regularly as we are always updating and improving this website!

© 2026 AC Service Tech, LLC.

bottom of page