top of page
Website Banner for LW link on MOBILE B.png

Carbon Monoxide Alarm vs Low Level CO Monitor

Updated: Feb 26


Today most people are aware of the invisible, odorless, poisonous gas of Carbon Monoxide or CO for short. Now we know that even low levels of CO can have long term health effects depending on exposure time, the health and age of the exposed person. Carbon Monoxide binds with the hemoglobin in the blood 300 times more than Oxygen. It is believed that Florence Nightingale's ailments may have stemmed from CO poisoning from her coal heater in Russia. Some haunted houses were actually from CO poisoning and its effects on the brain. It turns out the HVAC professional can be more effective than the exorcist! While the flu and cold is more prevalent in the winter, sometimes it is actually CO poisoning with similar symptoms. We need to be more aware!


What are Safe Levels For Carbon Monoxide?


What are safe levels for CO? It depends on who you ask, but I think we can all agree the less poisonous gas we breathe the better. It will be measured in How Many Parts of CO Per Million Parts of Air. This is referred to as PPM (Parts Per Million). The World Health Organization says 9-10 PPM for no more than 8 hours, 23-35 PPM no more than 1 hour and 90-100 PPM no more than 15 minutes. The National Institute for Occupational Safety and Health recommends no higher than 35 PPM over an 8 hour period. OSHA on the other hand set a limit of 50 PPM over an 8 hour period. These organizations may set limits on the CO PPM amount while sleeping, while active, and while working and you can read up on their recommended limits directly from them. However, for the sake of this article, we are just focusing on the fact that we need a method to accurately measure and notify us if CO is present.


Carbon Monoxide Alarm


So what does a CO Alarm sound off at? In the USA, CO alarms are UL rated (UL 2034/CSA 6.19) and will usually NOT sound off below 30 PPM! They may have a mandatory response of 70 PPM within 60-240 minutes, 150PPM within 10-50 Minutes, and 400 PPM within 4-15 minutes. By the time a CO alarm sounds off at those very high levels, it is an emergency! The first CO alarms where first introduced in 1992. In 1994 a strong weather inversion occurred in Chicago that trapped CO and other air pollutants at ground level and the Fire department responded to over 2000 emergency calls with 30 people in the ER. We knew a lot less about CO back then, but we knew the fire department was overrun with more calls than they could handle. This lead to the regulations of higher limits before an alarm would sound as an emergency.



Carbon Monoxide Monitor


What is a better solution than a high level alarm? Installing a low level CO monitor is a solution that will notify the occupants of the risk well before it becomes an emergency. By law, this cannot be called an alarm, thus the name "low level CO monitor". While different manufacturers have varying levels of notification, ideally it will have some warning at 10 PPM. This lower level warning will allow time for a professional to come and find the cause. While people often blame the furnace, it can also be a water heater, fireplace, unvented stove, oven, or even an attached garage. Yes, even an all electric house can suffer from an unhealthy level of CO just by backing a car in or out of the garage. It is important for the source to be identified and corrected although sometimes the source can be misleading such as a golf cart charger.


I recommend anyone in the trades or even on a camping trip to also carry a personal low level CO monitor. This will notify the worker when they are entering a potentially hazardous situation. One time mine went off in the summer when I was brazing an evaporator in a walk in cooler. Someone had closed the door while I was working, but my personal low level monitor alerted me to the hazard. When I started in the trade, wearing PPE such as gloves and safety glasses where not as common but now considered common sense. I hope having low level CO monitors in homes, businesses and on-person becomes just as common.


To learn more, I recommend reading "Carbon monoxide: a clear and present danger" by Bob Dwyer

HVAC E learn network has an online course for CO and combustion analysis https://hvacr.elearn.network/courses/combustion-analysis


You can find a variety of low level CO monitors and alarms at True Tech Tools! Use our promo code: acservicetech, for 8% off any order!


EPA Gov Link



Published: 11/29/2023 Author: Ty Branaman

About the Author: Ty is a nationally renowned HVACR Teacher that has over 20 years experience teaching high school, post secondary, and in-field technician students. Ty does on-site training events and ride-along training. Ty also makes instructional videos to share his knowledge. Ty can be reached at ty@love2hvac.com and his video library is available here: https://www.youtube.com/c/TyBranaman

7 Comments


Bevis Jason
Bevis Jason
a day ago

Whether you play for fun or aim for perfection, Retro Bowl 26 rewards smart thinking, sharp timing, and consistent team management.

Like

top game
top game
Jan 11

Gravity dances with every flight of an arrow in https://ragdollarchers.cc where the gentle momentum of physics shapes a quiet journey of precision and skill.


Like

Alex Saunders
Alex Saunders
Nov 20, 2025

Referring page from keurig I love the variety of flavors available, allowing me to explore new tastes every day. The machine is user-friendly, and the cleanup is a breeze, making it a joy to use. Overall, I’m thrilled with my decision and can’t wait to enjoy countless delicious cups of coffee! I purchased a Keurig machine, and it has truly transformed my coffee experience! The convenience of brewing a fresh cup in just minutes is a game-changer for my busy mornings.

Like

Fenpeiros
Fenpeiros
Oct 29, 2025

As a seasoned gambler who has danced with both fortune and misfortune, let me cut to the chase and say Fast Payout Casinos are the veritable crown jewel for any serious player. Imagine this: you've just hit that elusive jackpot after a marathon session; the adrenaline is surging through your veins, and you’re ready to revel in your victory lap. This is precisely when Fast Payout Casinos https://animeflix.city/ flex their unparalleled muscle by delivering those winnings straight into your pocket with lightning speed. No more nail-biting waits or cumbersome withdrawal processes that keep you from savoring your hard-won spoils. Fast payouts signify credibility - they respect the player's time, ensuring you're never sidelined by tedious bureaucracy while offering maximum control…

Edited
Like

Williamson ennith
Williamson ennith
Sep 16, 2025

This platform stands out with its commitment to user privacy and speedy gameplay. No Verification Casino provides a secure environment without lengthy sign-up processes. You can explore a diverse selection of high-quality https://no-verification-casinos.net/ slots and live dealer games. The simple design ensures that finding your favorite titles and managing your account is straightforward.

Like
Replying to

I never really thought about online casino games this deeply before, but reading this made me realize how much they’ve changed. I always imagined simple spinning reels, yet the idea of fast gameplay and no verification sounds more smooth and easy to start. I like the thought of exploring games without long sign up and just playing. Sometimes I just browse and see what feels simple and clear, and I also checked Fox Slots where everything feels easy to explore. For me it’s exciting to see how platforms keep becoming more user friendly and quick for players everywhere today.

Like
AccuTrak ad
danfoss ad
Asurity-Digital-Ads_High_Res_1080x360.jp
AC Service Tech Ad
Join Our Updates List!

AC Service Tech HVAC Training is made possible by continued support from our visitors, customers, and support from these Sponsors!

NAVAC LOGO Black_edited.png
Accutrak Logo
TruTech-Tools-Logo-Main (3)[528].png
HavenRGB-FC w_grey horz.png

AC SERVICE TECH, LLC

Updates List

Thanks for submitting!

Thanks for all your continued support! I appreciate all the comments, questions, and responses that I receive from each of you. I look forward to responding to many more! If you have an HVACR related question, drop it in the comment section of one of the YouTube videos at the AC Service Tech YouTube Channel and I will do my best to respond.

 

For business related inquires email us at info@acservicetech.com

Check back regularly as we are always updating and improving this website!

© 2026 AC Service Tech, LLC.

bottom of page