Refrigerant Charging & Service Procedures for Air Conditioning Book
118 Video Play List
This list of 118 VIDEOS correlates to the 2nd Edition Refrigerant Charging & Service Procedures
for Air Conditioning Paperback version.
If you have an E-book, most ereaders count the cover page, preamble, and table of contents as pages so the page numbers are pushed back exactly 12 pages. For example, on the list below, "Pg 13 Basic Refrigeration Cycle" would actually be pg 25 in an E-book.
Pg 1 Book Introduction https://youtube.com/shorts/G6S0ZIwjCMM
Pg 1 What Does the Term Air Conditioning mean? https://www.youtube.com/shorts/roD2A0Hmmho
Pg 4 Carbon Dioxide History https://youtu.be/dU-vbcf7Gv8
Pg 6 & 333 A2L Refrigerants R-32 and R-454B https://youtu.be/fpmCCmCFQLA
Pg 7 A2L Refrigerant Bottles https://youtube.com/shorts/FCxuwblMkPc
Pg 13 Basic Refrigeration Cycle https://youtu.be/WdS5tlPJGZc
Pg 17 4 Basic Components of an AC Unit https://youtube.com/shorts/fe5QsBaXB1Q
Pg 26 How Refrigerant Works in an Air Conditioner https://youtu.be/e4Q7A3gIEmE
Pg 27 Air Handler and Heat Pump Explained https://youtu.be/xt5KnHH4J8s
Pg 31 Heat Pump Refrigerant Cycle https://youtu.be/t3YMFXLPBRE
Pg 34 Explaining Subcooling Quickly https://youtube.com/shorts/vp8YNhbmywg
Pg 36 Explaining Superheat Quickly https://youtube.com/shorts/8RbKLHDk-zY
Pg 43 Determining the Refrigerant in a Recovery Bottle https://youtu.be/PvlvZsDCgYU
Pg 48 Temperature Glide https://youtube.com/shorts/FQaeidodKBc
Pg 51 Calibrating a Temp Meter and Sensors https://youtu.be/vdEoz6xp9R0
Pg 61 Manifolds, Gauge Stubs, and Probes https://youtu.be/FyVdQEm23_o
Pg 62 Evolution of the Refrigerant Manifold Gauge Set https://youtu.be/NKB0Tq41cOg
Pg 65 CoreMax Valve and Port Assembly https://youtu.be/yvprlk4C6vA
Pg 70 Tips for Connecting to Refrigerant Ports https://youtu.be/0PCdVkxGokY
Pg 71 Refrigerant Hose End Fittings https://youtu.be/qJgxe0vUyfw
Pg 72 Connecting to the Ports, Manifold Gage Set https://youtu.be/4pJNB0l2Vjo
Pg 81 Uses of a VCRT https://youtube.com/shorts/zcFazXvZjB0
Pg 85 Two Position Service Valves https://youtu.be/WlJTY75oSqE
Pg 86 Service Valve Types and Access Fittings https://youtu.be/J0hyVhJyyD0
Pg 87 Three Position Service Valves https://youtu.be/9hN7u8iT8vI
Pg 90 Measuring Superheat & Subcooling https://youtu.be/2SEDe0v8VPY
Pg 91 Before Checking the Refrigerant Charge https://youtu.be/NOWQsrjm4AY
Pg 95 Checking the Charge, Subcooling https://youtu.be/eQgquFngPUM
Pg 95 & 251 R-32 and R-454B Checking the Charge https://youtu.be/rRvYVH0g218
Pg 99 Superheat & Total Superheat Explained https://youtu.be/vLGzCOUf1X8
Pg 101 Tools to Check Wet Bulb Temperature https://youtu.be/bUU8zKfr22g
Pg 103 Finding Target Superheat to Check the Charge https://youtu.be/MJMe9PPNjI8
Pg 104 Checking the Charge, Total Superheat Method https://youtu.be/DLDgfj5s4qg
Pg 104 Measuring the Refrigerant Charge, Fixed Orifice Systems https://youtu.be/cQgwrFxm_iQ
Pg 105 Methods for Checking the Refrigerant Levels https://youtu.be/EHzDDcnzcH8
Pg 105 Checking the Charge with Superheat https://youtu.be/sCIsw2FKC0M
Pg 107 Explaining Delta T https://youtu.be/VwHAMwJReog
Pg 108 Condensate From an Air Conditioner https://youtube.com/shorts/wS8ea32Jypg
Pg 109 Subcooling & Superheat, TXVs & Fixed Orifices https://youtu.be/ZE7oiVsVpfU
Pg 110 Check R-22 Refrigerant Charge, Subcooling https://youtu.be/NUKkwqDNq1E
Pg 110 Check R-410A Refrigerant Charge, Subcooling https://youtu.be/0zsckt86Who
Pg 110 Check R-410A Refrigerant Charge, Subcooling, More Methods https://youtu.be/sUiyiUjVpWc
Pg 111 Check R-410A Refrigerant Charge, Superheat https://youtu.be/hgJbuaWmkus
Pg 111 R-22 & R-410A AC Operating Pressures https://youtu.be/5pQUkG43gAI
Pg 111 Check the Charge on a TXV System, Subcooling https://youtube.com/shorts/Q6smzWNAz0k
Pg 122 What is a Liquid Vaporizer? https://youtu.be/42fPODYfLq8
Pg 141 Charging & Recovery, Digital Probes/Gauges https://youtu.be/obZgCt5d8bg
Pg 142 Charging Refrigerant, Wireless Probes https://youtu.be/saOTWm038JE
Pg 143 Leak Testing at the Ports https://youtu.be/xyBM4PLQXK0
Pg 150 Charging Refrigerant, the Subcooling Method https://youtu.be/9l3n7yQ_N5k
Pg 152 Charging R-410A into an Air Conditioner, Low https://youtu.be/-pN9EoUZX8c
Pg 158 Methods for Recovering Refrigerant https://youtu.be/yXJNuMmEPog
Pg 164 Refrigerant Recovery Tips https://youtu.be/DW2nf5bDoXY
Pg 165 Preparation of a Recovery Bottle https://youtu.be/DS8m0fYw48Q
Pg 171 Step by Step Refrigerant Recovery https://youtu.be/8pDp-q2dr_g
Pg 172 Recovery Machine Hose Setups https://youtu.be/oOMlOvOsFk8
Pg 172 Refrigerant Recovery Preparation & Procedure https://youtu.be/5XMlQCfdiu8
Pg 174 Refrigerant Recovery Procedure https://youtu.be/6F-u55EoMcU
Pg 182 The Pump Down Procedure https://youtu.be/xkQ6cxkaps4
Pg 186 Line Set Cleaning Methods https://youtu.be/sDji7wSt2MA
Pg 186 Eccentric Flaring Tools https://youtu.be/eF1e39Q6PaU
Pg 187 Silver Soldering & Brazing https://youtu.be/hrXX4IjjChM
Pg 188 Brazing and Leak Testing an Air Conditioner https://youtu.be/E1lEZwgmW9w
Pg 194 Where to Find Leaks on AC Units https://youtu.be/mjBdlwe687A
Pg 195 Ultrasonic Leak Detector https://youtu.be/JbXxE-WlQdo
Pg 202 Vacuum Procedure Tips https://youtu.be/rhmqHBi9a-o
Pg 203 Vacuum Pump Hose Setups https://youtu.be/TllrD0Mt2LU
Pg 204 Single vs Two Hose Vacuum Setup https://youtu.be/J4QvgpYFS9U
Pg 212 Step By Step Vacuum Pump Setup https://youtu.be/_VX9tlznCJQ
Pg 215 Vacuuming, Weighing Refrigerant, Checking the Charge https://youtu.be/PfdL3kZ3C6I
Pg 221 Vacuum Gauge Problems https://youtu.be/Ks3MtPmXDUE
Pg 223 Vacuum Pump Oil Basics https://youtu.be/09wD3pj3P2s
Pg 225 Triple Evacuation Method https://youtu.be/81EeY7SFYJc
Pg 227 Checking the Charge, Charging Jacket https://youtu.be/OmQQcjmNLgw
Pg 228 Checking the Charge, Low Outdoor Temps https://youtu.be/_hAkQpLT35g
Pg 229 Metering Device Bypass Features https://youtu.be/LdwrtJOszq0
Pg 231 Measuring Superheat & Subcooling without Pressure https://youtu.be/LWW6p6EnrmQ
Pg 243 Ambient + Rules https://youtu.be/3rVxcFIFyrk
Pg 245 Frozen Evaporator Coil Troubleshooting https://youtu.be/wZctpvMtXMM
Pg 245 Low Saturated Temperatures & Pressures https://youtu.be/gsgC6mV4Ip0
Pg 245 Why an Evaporator Coil Freezes https://youtu.be/fGZmQcLZ-5E
Pg 245 Checking Very Low Refrigerant Charge https://youtu.be/Oekdgkw4dys
Pg 246 Troubleshooting a Frozen Suction Line https://youtu.be/uW5sMlWr2WY
Pg 247 Low Indoor Airflow Troubleshooting https://youtu.be/ob44e8fVhwk
Pg 248 Frozen Indoor Coil, Low Refrigerant Charge https://youtu.be/gD-N6Q60Hdg
Pg 249 Liquid Line Restriction https://youtu.be/_x1aOij_uOI
Pg 250 Liquid Line Restriction, Low Airflow, Low Charge https://youtu.be/zOd2G10F-YY
Pg 250 Liquid Line Restriction Explained https://youtu.be/_yLMv7T2hhM
Pg 269 Wrong TXV for the Refrigerant in the System https://youtu.be/eZbWp4DEXBI
Pg 271 Airflow Basics https://youtu.be/XqigOg-Bh90
Pg 272 Adjusting HVAC Blower Speed CFM https://youtu.be/f79rrGsWNvM
Pg 273 Measuring Airflow, Temp Rise Formula https://youtu.be/agAfV3Yqb7U
Pg 275 Measuring Airflow CFM, Hot Wire Anemometer https://youtu.be/0wWYsAn6eGo
Pg 278 Measuring Airflow CFM, TrueFlow Grid https://youtu.be/89IKljbgKgA
Pg 281 Measuring Static Pressure https://youtu.be/eFmDmk1Siqc
Pg 282 Finding Airflow Problems https://youtu.be/umJe1ow45I8
Pg 284 Low Airflow Causes https://youtu.be/T5eBsC_MZAI
Pg 286 Determining if an AC Coil is Clogged with Dust https://youtu.be/CLRMISQCg0A
Pg 287 Measuring Duct Leakage https://youtu.be/eqXR1J-JnRQ
Pg 289 Metering Device Types https://youtu.be/-4ZPUkxYkLo
Pg 291 Replacing a Piston with a TXV https://youtu.be/ETiXUeJG5tc
Pg 296 TXV, Superheat https://youtube.com/shorts/fc3eTzlgFCg
Pg 296 TXV Explained https://youtu.be/cORHWATpwUc
Pg 297 The 3 TXV Operations https://youtu.be/WkgshvMOx00
Pg 298 What’s Inside a TXV? https://youtu.be/p2XFT9j4nFw
Pg 300 Should You Replace a Bad TXV with a Piston? https://youtu.be/Cd_2-x3kdyY
Pg 302 LEV/EEV Operation and Troubleshooting https://youtu.be/B_j73X0gxC0
Pg 303 Explaining EEVs https://youtube.com/shorts/nsLMz2nRSwA
Pg 303 EEV Operations and Testing https://youtu.be/LzvVjvUpOVM
Pg 311 Scroll Compressor Operation https://youtu.be/e9vORn5Vwuc
Pg 318 Line Set Corrosion https://youtu.be/4WCnz34SiX8
Pg 324 Suction Line Accumulator Tank Explained https://youtu.be/WePMCkeJm5U
Pg 324 Mini Split Accumulator Tank https://youtube.com/shorts/V-xGxG5wOEc
Pg 326 Heat Pump Reversing Valve https://youtu.be/QLxQQElP1nA
Pg 330 Walk-In Box Refrigeration Cycle https://youtu.be/wjeoHrP9Nkg
Pg 330 Liquid Line Receiver Tank https://youtu.be/S9bYjfdLmJ8
Pg 331 Liquid Line Solenoid Valvehttps://youtu.be/fnny2VpdHiI
Pg 335 R-454B Dissipation Control Board Installation https://youtu.be/_SDRKdZ0WX4