Jul 30, 2025 ∙ 5 min
How to Read a Tape Measure in Inches and Fractions!
When teaching students how to use and read a tape measure for the first time, I have a go-to set of items to facilitate the training. I use 13 pieces of wood with 26 measurements labeled A-Z. Each piece has two letters, one for each dimension to be measured. I then give each student a fraction layout sheet for an inch and another sheet that they can write their answers on for each letter measured, A through Z. I explain the 1/2", 1/4", 1/8" and 1/16" fractions, full one inch measurements, and...

6280
175
28
Jul 15, 2025 ∙ 1 min
Make Sure to Connect You Gauge Quickly To Prevent Contamination!
If you remove the vapor access port cap on a running air conditioning system, the low temperature brass on the inside of the port will condense water vapor from the air surrounding the port directly onto the port. This is because the air surrounding the port is often below the dew point. Don't remove the port cap until you are immediately ready to connect the gauge. Don't even connect the gauge unless you suspect a problem with the refrigerant charge level. We want to reduce the chances of...

1362
116
7
Jul 15, 2025 ∙ 1 min
Do You Need Locking Caps On Refrigerant Access Ports!
After servicing or adding refrigerant to an air conditioning system, add locking caps to the service ports if the system is in an accessible area. This reduces the chance of someone tampering with the refrigerant charge. The IMC code that requires this may or may not be adopted/enforced by your local municipality. However, it is a really good idea to do so to keep everyone safe and to keep the refrigerant charge intact. IMC Code 1101.10: " Refrigerant circuit access ports located outdoors...

1254
31
6
Craig Migliacco

Craig Migliacco

Admin
More actions

AC Service Tech HVAC Training is made possible by continued support from our visitors, customers, and support from these Sponsors!

NAVAC LOGO Black_edited.png
Accutrak Logo
TruTech-Tools-Logo-Main (3)[528].png
HavenRGB-FC w_grey horz.png

AC SERVICE TECH, LLC

Updates List

Thanks for submitting!

Thanks for all your continued support! I appreciate all the comments, questions, and responses that I receive from each of you. I look forward to responding to many more! If you have an HVACR related question, drop it in the comment section of one of the YouTube videos at the AC Service Tech YouTube Channel and I will do my best to respond.

 

For business related inquires email us at info@acservicetech.com

Check back regularly as we are always updating and improving this website!

© 2026 AC Service Tech, LLC.

bottom of page