Thanks for all your continued support! I appreciate all the comments, questions, and responses that I receive from each of you. I look forward to responding to many more! If you have an HVACR related question, drop it in the comment section of one of the YouTube videos at the AC Service Tech YouTube Channel and I will do my best to respond.

 

For business related inquires email us at info@acservicetech.com

Check back regularly as we are always updating and improving this website!

Updates List

© 2019 AC Service Tech, LLC.

0

This Teacher's E-Book is dedicated to those who are eager to teach the HVACR Trade and Refrigerant Charging/Troubleshooting Practices.

 

In this book, you will find Step by Step Procedures for preparing an air conditioning and heat pump system for refrigerant, reading the manifold gauge set, measuring the refrigerants charge level, and troubleshooting problems with the system’s refrigerant flow. This book differs from others as it gives key insights into each procedure along with tool use from a technician’s perspective, in language that the technician can understand.

 

This book explains the refrigeration cycle of air conditioners and heat pumps, refrigerant properties, heat transfer, the components included in the system, the roles of each component, airflow requirements, and common problems.

 

Procedures Included:

  • Pump Down
  • Vacuum and Standing Vacuum Test
  • Recovery and Recovery Bottle use
  • Refrigerant Manifold Gauge Set and Hose Connections
  • Service Valve Positions and Port Access
  • Preparation of the System for Refrigerant
  • Refrigerant Charging and Recovery on an Active System
  • Troubleshooting the Refrigerant Charge and System Operation

Teacher's Ebook Refrigerant Charging and Service Procedures for Air Conditioning

$30.00Price
  • Secure PDF intended for presentation and instructional use.

  • File is to be used in the agreed upon manner according to the purchase agreement between AC Service Tech LLC and the instructional institution that has purchased this product.

Save $5 when you purchase the Paperback, Cards, and Ebook together!

Enter Promo Code

Dec19CPE
at the checkout!

Bundle and Save!

Save $5 when you purchase the Paperback and Cards together!

Enter Promo Code

Dec19CP
at the checkout!

Save $5 when you purchase the Paperback and Ebook together!

Enter Promo Code

Dec19PE
at the checkout!

Need an E-reader?

Try downloading one of the following apps to be sure you can read our book right on your phone!

Google Play Books icon.jpg

Google Play Books

For use on android and Google devices

Apple_Books icon.png

Apple iBooks

For use on iPhones and iOS devices